Opinion · 29 Jun 2025
Conference abstractPublished 4 Jan 2021
A Phantom study for optimization of radiation dose and evaluation of image quality for CT head in Pediatric Population
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Pediatric CT imaging have increased rapidly with advancement in CT hardware and soft wares but radiation pose major adverse effects, as children’s are 2-3 times more vulnerable to effect of radiation. In order to optimize radiation dose in CT, we must select suitable scanning protocol such as kVp, mAs and Iterative Reconstruction techniques (IR) that corresponds to region of examination and patient age or size. With conventional reconstruction technique such as filtered back projection (FBP), excessive dose reduction results in increased noise and provides suboptimal image for diagnostic interpretation. Hence, CT manufacturers have introduced hybrid Iterative Reconstruction (IR) techniques to optimize radiation dose to patients without affecting image quality. Therefore, the objective of this study is to optimize radiation dose by developing and implementing low dose pediatric CT head protocol and to evaluate the image quality by using pediatric head phantom. Materials & Methods: Pediatric head phantom was scanned using 128 slice Philips CT Scanner with different tube voltage and tube current - exposure time products setting with reconstruction mode iDose4. The radiation dose was measured based on Volumetric CT Dose Index (CTDIv) that was noted from the CT console. Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Figure of Merit (FOM) was calculated to access the image quality. Results: The radiation dose and image quality was assessed for different kV and mAs setting. For less than 1-year age, the CTDIv was 7.21mGy and noise was 5 for 80 kV and 150 mAs. For 1 – 5 years age, the CTDIv was15.42 mGy and noise was 5 for 100 kV and 160 mAs. Conclusion: The optimum protocols (kVp, mAs, IR) are derived based on image quality (SNR, CNR, FOM) and radiation dose (CTDIv). For pediatric CT head aged less than 1year 80 kV, 150 mAs and for 1- 5years age 100 kV, 160 mAs with reconstruction mode iDose4 level-3 are found to be optimum scanning protocol. Keywords: Diagnostic Reference levels (DRLs), Dose Length Product (DLP), Volumetric Computed Tomography Dose Index (CTDIvol)
Keywords
Subjects
Oncology & CancerAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Allied Academies does not store it.
More from this journal
The newest in Journal of Clinical Oncology and Cancer Research.
Opinion · 29 Jun 2025
Molecular Biomarkers for Early Detection and Prognosis of Breast Cancer
Commentary · 29 Jun 2025
Targeted Therapy in Non-Small Cell Lung Cancer: Current Landscape and Future Directions
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Clinical Oncology and Cancer Research
- SubjectOncology & Cancer
- BylineArticles whose byline prints “Priyanka”
