ArticlePublished 2019

Minimal agreement between basophil activation test and immunoassay in diagnosis of penicillin allergy.

Authors: Brenda Leecyous, Faizal Bakhtiar, Min Moon Tang, Zailatul Hani Mohamad Yadzir

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: Basophil activation test (BAT) and immunoassays are the most widely used in vitro tests to diagnose IgE-mediated allergic reactions to penicillin. However, study to determine if one test is interdependent from another is limited. Objective: The present study aimed to measure the agreement between BAT and immunoassay in diagnosis of penicillin allergy. Method: Twenty-five adult patients with clinical history of immediate allergic reactions to penicillin whom referred to the Allergy Clinic, Hospital Kuala Lumpur (HKL) were assessed. BAT was performed using penicillin G (Pen G), penicillin V (Pen V), penicilloyl-polylysine (PPL), minor determinant mix (MDM), amoxicillin (Amx) and ampicillin (Amp) within 12 months from the reaction. Immunoassay of total IgE (tIgE) and specific IgE (sIgE) antibodies to Pen G, Pen V, Amx and Amp were quantified. Skin prick test (SPT) using PPL-MDM, Amx, Amp and Clavulanic acid were also performed. Results: Minimal agreement was observed between BAT and immunoassay (Cohen’s kappa Index, k=0.25). Two patients were BAT-positive, and four patients were sIgE-positive. Of two BAT- positive patients, one patient is positive to Amx (59.27%, SI=59) and Amp (82.32%, SI=82) but sIgE-negative to all drug tested. This patient also SPT-positive to both drugs. Another patient is BAT-positive to Pen G (10.18%, SI=40), Pen V (25.07%, SI=100) and Amp (19.52%, SI=79). The results were in concordance with sIgE testing results (Pen G=10.7 kU/L, Pen V=10.8 kU/L, Amp=8.29 kU/L) except for Amx. In sIgE immunoassay, four patients were sIgE-positive to at least one of the drugs tested. The sIgE level of three patients were between low (0.35-0.69 kU/L) and moderate (0.70-3.49 kU/L) and they were BAT-negative. One BAT- positive patient has high level of sIgE antibodies (3.50-17.5 kU/L) and this patient also has relatively high specific to total IgE ratio ≥ 0.002 (0.004-0.007). Conclusions: The agreement between BAT and immunoassay is minimal. Performing both tests may not increase the sensitivity of allergy diagnosis work-up for immediate reactions to penicillin.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Allied Academies does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • SubjectImmunology & Microbiology
  • BylineArticles whose byline prints “Brenda Leecyous”
  • BylineArticles whose byline prints “Faizal Bakhtiar”
  • BylineArticles whose byline prints “Min Moon Tang”
  • BylineArticles whose byline prints “Zailatul Hani Mohamad Yadzir”