Research articlePublished 28 Feb 2017

Monte Carlo study of a flattening filter-free 6 MV photon beam using the BEAMnrc code

Authors: Ankit Kajaria, Neeraj Sharma, Shiru Sharma, Satyajit Pradhan, Abhijit Mandal, Lalit Aggarwal M

Biomedical Research

Volume 28 · Issue 4 · Pages 1566–1573

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Flattening Filter Free (FFF) photon beams have different dosimetric properties from those of flattened beams. The aim of this study is to evaluate the basic dosimetric properties of a flattening filter free 6 MV photon beam. A Monte Carlo simulation model was developed for a 6 MV photon beam based on Varian Clinic 600 unique performance linac operated with/without a flattening filter and dosimetric features including central axis absorbed dose, beam profiles and photon and electron spectra were calculated for flattened and unflattened cases separately. Absolute depth dose calculations showed an increase in dose rate with a factor of more than 2.4 for the unflattened 6 MV photon beam which is dependent on the depth. Percentage Depth Doses (PDDs) values were found to be lower for unflattened beam for all field sizes. The total Scatter Correction Factor (SCP) were found to have less variation with field sizes for unflattened beam indicating that removing of the filter from the beam line can reduce significant amount of head scatter. However surface doses were found to be higher for the unflattened beam due to more contamination electrons and low energy photons in the beam. Our study showed that increase in the dose rate and lower out-of-field dose could be considered as practical advantages for unflattened 6 MV photon beams.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Allied Academies does not store it.

Try:

Similar by topic

More from this journal

The newest in Biomedical Research.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiomedical Research
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Ankit Kajaria”
  • BylineArticles whose byline prints “Neeraj Sharma”
  • BylineArticles whose byline prints “Shiru Sharma”
  • BylineArticles whose byline prints “Satyajit Pradhan”
  • BylineArticles whose byline prints “Abhijit Mandal”
  • BylineArticles whose byline prints “Lalit Aggarwal M”