Research articlePublished 19 Sep 2017

Fusion images of perfusion- and diffusion-weighted MR imaging: A simple diagnostic approach of ischemic penumbra selection in patients with acute ischemic stroke

Authors: Tian-Le Wang, Li Zhu, Chun-Hong Hu, Shen-Chu Gong, Hong-Biao Jiang, Hai-Tao Chen, Jia Li

Biomedical Research

Volume 28 · Issue 17 · Pages 7578–7582

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objective: This study aimed to assess the diagnostic value of ischemic penumbra (IP) selection using fusion images of Perfusion-Weighted Imaging (PWI) and Diffusion-Weighted Imaging (DWI), compared with volumetric-based Perfusion-Diffusion Mismatch (PDM) in patients with Acute Ischemic Stroke (AIS). Materials and Methods: A total of 42 patients with a confirmed diagnosis of AIS were included in this retrospective study. DWI images were overlaid onto PWI images to obtain fused images using 3D fusion software. Two experienced neuroradiologists estimated the qualitative PDM using fused and paired images, respectively. The results were comparable to the results of volumetric-based PDM, which were obtained using semi-automated quantitative software. Results: The time consumed for qualitative measurement was significantly different among different assessment methods, but no significant differences were found in time consumed for qualitative PDM assessment using fused and paired images. The qualitative PDM was significantly lower than quantitative PDM. The two qualitative PDM subgroups related to quantitative PDM had a sensitivity of 84.21% and 77.78%, specificity of 78.26% and 60.86%, positive predictive rate of 94.12% and 87.50%, and negative predictive rate of 90.00% and 82.35%, respectively. A high consistency in qualitative PDM assessment using fused images (Kappa=0.762) but a low consistency in qualitative PDM assessment using paired images between two observers were observed (Kappa=0.561). Conclusions: The fusion images of DWI and PWI provided information comparable to the information provided by volumetric-based PDM. It took less time and hence might be an effective approach for IP selection in patients with AIS.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Allied Academies does not store it.

Try:

More from this journal

The newest in Biomedical Research.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiomedical Research
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Tian-Le Wang”
  • BylineArticles whose byline prints “Li Zhu”
  • BylineArticles whose byline prints “Chun-Hong Hu”
  • BylineArticles whose byline prints “Shen-Chu Gong”
  • BylineArticles whose byline prints “Hong-Biao Jiang”
  • BylineArticles whose byline prints “Hai-Tao Chen”
  • BylineArticles whose byline prints “Jia Li”